K. Rogers, Biosensors for environmental applications, Biosensors and Bioelectronics, vol.10, issue.6-7, pp.533-541, 1995.
DOI : 10.1016/0956-5663(95)96929-S

URL : http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.472.9338

P. Pandard, P. Vasseur, and D. M. Rawson, Comparison of two types of sensors using eukaryotic algae to monitor pollution of aquatic systems, Water Research, vol.27, issue.3, pp.427-432, 1993.
DOI : 10.1016/0043-1354(93)90043-H

G. Samson and R. Popovic, Use of algal fluorescence for determination of phytotoxicity of heavy metals and pesticides as environmental pollutants, Ecotoxicology and Environmental Safety, vol.16, issue.3, pp.272-278, 1988.
DOI : 10.1016/0147-6513(88)90056-5

G. A. Rechnitz and M. Y. Ho, Biosensors based on cell and tissue material, Journal of Biotechnology, vol.15, issue.3, pp.201-218, 1990.
DOI : 10.1016/0168-1656(90)90027-9

C. Durrieu and C. Tran-minh, Optical Algal Biosensor using Alkaline Phosphatase for Determination of Heavy Metals, Ecotoxicology and Environmental Safety, vol.51, issue.3, pp.206-209, 2002.
DOI : 10.1006/eesa.2001.2140

URL : https://hal.archives-ouvertes.fr/emse-00520278

F. Gilbert, F. Galgani, and Y. Cadiou, Rapid assessment of metabolic activity in marine microalgae: application in ecotoxicological tests and evaluation of water quality, Marine Biology, vol.69, issue.2, pp.199-205, 1992.
DOI : 10.1007/BF00702462

M. Naessens, J. C. Leclerc, and C. Tran-minh, Fiber Optic Biosensor Using Chlorella vulgaris for Determination of Toxic Compounds, Ecotoxicology and Environmental Safety, vol.46, issue.2, pp.181-185, 2000.
DOI : 10.1006/eesa.1999.1904

URL : https://hal.archives-ouvertes.fr/emse-00494383

S. V. Dzyadevych, A. A. Ga, S. V. Patskovsky, V. N. Arkhipova, A. P. Soldatkin et al., Thin-film conductometric sensors for enzyme biotransducers, Russ. J. Electrochem, issue.8, pp.30-987, 1994.

S. V. Dzyadevych, A. P. Soldatkin, and J. M. Chovelon, Assessment of the toxicity of methyl parathion and its photodegradation products in water samples using conductometric enzyme biosensors, Analytica Chimica Acta, vol.459, issue.1, pp.33-41, 2002.
DOI : 10.1016/S0003-2670(02)00083-1

F. Pariente, L. Hernandez, and E. Lorenzo, Amperometric sensor based on the alkaline phosphatase activity, Bioelectrochemistry and Bioenergetics, vol.27, issue.1, pp.73-87, 1992.
DOI : 10.1016/0302-4598(92)85014-7

C. Chouteau, S. Dzadevych, J. M. Chovelon, and C. Durrieu, Development of novel conductometric biosensors based on immobilised whole cell Chlorella vulgaris microalgae, Biosensors and Bioelectronics, vol.19, issue.9, pp.1089-1096, 2004.
DOI : 10.1016/j.bios.2003.10.012

C. Durrieu, I. Badreddine, and C. Daix, A dialysis system with phytoplankton for monitoring chemical pollution in freshwater ecosystems by alkaline phosphatase assay, Journal of Applied Phycology, vol.15, issue.4, pp.289-295, 2003.
DOI : 10.1023/A:1025165727616

P. Vasseur and P. Pandard, Influence of some experimental factors on metal toxicity to Selenastrum capricornutum Toxic. Assess, pp.331-343, 1988.

C. Tran-minh, Immobilized Enzyme Probes for Determining Inhibitors, Ion Sel. Electrode R, vol.7, pp.41-75, 1985.
DOI : 10.1016/B978-0-08-034150-7.50006-1

URL : https://hal.archives-ouvertes.fr/emse-00589781

C. Tran-minh, P. C. Pandey, and S. Kumaran, Studies on acetylcholine sensor and its analytical application based on the inhibition of cholinesterase, Biosensors and Bioelectronics, vol.5, issue.6, pp.461-471, 1990.
DOI : 10.1016/0956-5663(90)80035-C

URL : https://hal.archives-ouvertes.fr/emse-00569329

C. Cremisini, S. Di-sario, J. Mela, R. Pilloton, and G. Palleschi, Evaluation of the use of free and immobilised acetylcholinesterase for paraoxon detection with an amperometric choline oxidase based biosensor, Analytica Chimica Acta, vol.311, issue.3, pp.311-273, 1995.
DOI : 10.1016/0003-2670(94)00618-V

M. S. Ayyagari, S. Kamtekar, R. Pande, K. A. Marx, J. Kumar et al., Biosensors for pesticide detection based on alkaline phosphatase-catalyzed chemiluminescence, Materials Science and Engineering: C, vol.2, issue.4, pp.191-196, 1995.
DOI : 10.1016/0928-4931(95)00077-1

G. Sánchez, F. Díaz, A. Ramos-peinado, M. C. Belledone, and C. , Free and sol???gel immobilized alkaline phosphatase-based biosensor for the determination of pesticides and inorganic compounds, Analytica Chimica Acta, vol.484, issue.1, pp.45-51, 2003.
DOI : 10.1016/S0003-2670(03)00310-6

R. A. Conyers, D. J. Birkett, F. C. Neale, S. Posen, and J. Brudenell, The action of EDTA on human alkaline phosphatases, Biochimica et Biophysica Acta (BBA) - Enzymology, vol.139, issue.2, pp.363-371, 1967.
DOI : 10.1016/0005-2744(67)90040-X

M. Naessens, J. C. Lerclerc, and C. Tran-minh, Fiber Optic Biosensor Using Chlorella vulgaris for Determination of Toxic Compounds, Ecotoxicology and Environmental Safety, vol.46, issue.2, pp.181-185, 2000.
DOI : 10.1006/eesa.1999.1904

URL : https://hal.archives-ouvertes.fr/emse-00494383

C. Védrine, J. C. Leclerc, C. Durrieu, and C. Tran-minh, Optical whole-cell biosensor using Chlorella vulgaris designed for monitoring herbicides, Biosensors and Bioelectronics, vol.18, issue.4, pp.457-463, 2003.
DOI : 10.1016/S0956-5663(02)00157-4