Runaway reaction of non-tempered chemical systems: Development of a similarity vent-sizing tool at laboratory scale - Mines Saint-Étienne
Article Dans Une Revue Journal of Loss Prevention in the Process Industries Année : 2008

Runaway reaction of non-tempered chemical systems: Development of a similarity vent-sizing tool at laboratory scale

Résumé

A new experimental “similarity” vent-sizing tool (A/V ratio) for non-tempered chemical systems was developed. It combines the advantages of both the Design Institute for Emergency Relief Systems (DIERS) method (laboratory scale) and UN method (less overconservative). This tool is based on the VSP2 adiabatic calorimeter. It uses a 0.1 l test cell and allows blowdown experiments to be carried out in the 0.9×10−3 m−1

Dates et versions

emse-00497989 , version 1 (06-07-2010)

Identifiants

Citer

Luc Véchot, Jean-Pierre Bigot, Daniele Testa, Marc Kazmierczak, Patricia Vicot. Runaway reaction of non-tempered chemical systems: Development of a similarity vent-sizing tool at laboratory scale. Journal of Loss Prevention in the Process Industries, 2008, 21 (4), pp.359-366. ⟨10.1016/j.jlp.2008.01.005⟩. ⟨emse-00497989⟩
116 Consultations
0 Téléchargements

Altmetric

Partager

More